Parameter | Unit | Specaication | |
Type | – | AF-SWC | |
Rated Load(N.L) Depends On Strip Size |
KG | … | |
Rated Sensitivity(N.S) | mV/V | 1.3…2.0 | |
N.S Differences Between Sensors | %N.S. | 2 | |
Accuracy | – | 0.25% | |
Balance | mV/V | ±0.20 | |
Maximum Working Voltage | V | 12 | |
Minimum Distance To Socket | cm | 25 | |
Temperature Range | Compensate | ℃(℉) | -10…+40(+14…+104) |
Working | -20…+60(-4…+140) | ||
Store | -20…+70(-4…+158) | ||
Minimum Insulation Resistance (Voltage Test: 100V) |
GΩ | 4 | |
Input Resistance | Ω | 350..400 | |
Output Resistance | Ω | 350±1.5 | |
Load Limit | Safety | %N.L. | 120 |
Optimal | 150 | ||
Cable | Type | – | 4*0.14mm²∅4.3 |
Terminal | – | USB | |
Standard Length | m | 0.75 | |
Material | – | Polyurethane(PU) | |
Sensor | Material | – | Plating |
Surface Treatment | – | Aluminum | |
Protection Level | – | IP65 |