Products

Products

Elevator Machine Power Cable VVR/VVRP 0.6/1KV

PRODUCTION APPLICATION:
Transmit power to the elevators machine.
RATED VOLTAGE: This product is fit for the rated voltage 600/1KV and below
WORK TEMPERATURE:
Used under the normal conditions, the conductor temperature iscable is available from -15℃ to 40℃ environment.

Code names and meanings
T Elevator Cable V PVC Insulation V PVC Jacket
B Flat P Shieled TV Visualwire
G Supporting steel S Twisted Pair R Flexible

Hot Product

Main Product

Elevator Machine Power Cable VVR/VVRP 0.6/1KV

Elevator Motor Machine Power Cable VVR/VVRP 0.6/1KV

VVR 0.61/1KV
specification conductor structure overall dimension Ω/km
max conductor resistance at 20℃
MΩ.km
max insulation resistance at 70℃
uppper limit lower limit
3×10 182/0.26 16.5 19 1.91 0.0056
4×4 77/0.26 12.5 15 4.95 0.0070
4×6 112/0.26 14.5 17 3.3 0.0060
4×10 182/0.26 18.2 20 1.91 0.0056
5×4 77/0.26 14.5 7 4.95 0.0070
5×6 112/0.26 16.1 17 3.3 0.0060
5×10 182/0.26 20.0 18.6 1.91 0.0056
7×6 112/0.26 17.9 22.5 3.3 0.0060
3×6+1×4 112/0.26
77/0.26
14.4 17 3.3
4.95
0.0060
0.0070
3×10+1×6 182/0.26
112/0.26
18.2 20.8 1.91
3.30
0.0056
0.0060
VVRP 0.6/1KV
specification conductor structure overall dimension Ω/km
max conductor resistance at 20℃
MΩ.km
max insulation resistance at 70℃
uppper limit lower limit
3×6 112/0.26 13.3 15.8 3.3 0.0060
3×10 182/0.26 16.5 19 1.91 0.0056
4X6 112/0.26 15.2 17.8 3.3 0.0060
4×10 182/0.26 18.2 20.8 1.91 0.0056

 

 

CONTACT US FOR ANY INQUESTIONS