E27 indicates a door frame self-learning failure.
Ⅰ. The commonly used NICE900 door machine inverters mainly include the following three types, with different output power:
NICE-D-A-SOP2 (200W)
NICE-D-A-SOP4 (400W)
NICE-D-A-SOP7 (750W)
Ⅱ. Fault Causes:
1.The learned door width data from self-learning is less than 20.
2. Distance control operation is performed before door width self-learning.
Ⅲ. Troubleshooting Methods:
1.Check the elevator door operator encoder wiring and related parameters.
2.Inspect the mechanical system of the elevator door operator.
3.Perform door width pulse self-learning before distance control operation.