Elevator Shaft Cable RRVS/RRVSP 300/500V
RVVS 300/500V 0.5-0.75(2-30core),0.5-0.75(2-30core)+1-2(1core) | |||||
specification | conductor structure | overall dimension | Ω/km max conductor resistance at 20℃ |
MΩ.km max insulation resistance at 70℃ |
|
uppper limit | lower limit | ||||
1x2x0.75 | 30/0.18 | / | 6 | 26 | 0.011 |
2x2x0.5+1×1 | 28/0.15 32/0.20 | 7.4 | 9.4 | 39.0 19.5 |
0.013 0.010 |
4x2x0.5+1×1 | 28/0.15 32/0.20 | 9.6 | 11.6 | 39.0 19.5 |
0.013 0.010 |
6x2x0.5+1×1 | 28/0.18 32/0.20 | 11.0 | 13 | 39.0 19.5 |
0.013 0.010 |
2x2x0.75+1×2 | 30/0.18 38/0.26 | 7.8 | 9.8 | 26.0 9.98 |
0.011 0.009 |
3x2x0.75+1×2 | 30/0.18 38/0.26 | 9.4 | 11.4 | 26.0 9.98 |
0.011 0.009 |
4x2x0.75+1×2 | 30/0.18 38/0.26 | 10.4 | 12.4 | 26.0 9.98 |
0.011 0.009 |
5x2x0.75+1×2 | 30/0.18 38/0.26 | 11.6 | 13.6 | 26.0 9.98 |
0.011 0.009 |
6x2x0.75+1×2 | 30/0.18 38/0.26 | 11.6 | 13.6 | 26.0 9.98 |
0.011 0.009 |
7x2x0.75+1×2 | 30/0.18 38/0.26 | 12.0 | 14 | 26.0 9.98 |
0.011 0.009 |
RVVSP 300/500V 0.5-1(2-30 core) | |||||
specification | conductor structure | overall dimension | Ω/km max conductor resistance at 20℃ |
MΩ.km max insulation resistance at 70℃ |
|
uppper limit | lower limit | ||||
2x2x0.5 | 28/0.15 | 8.8 | 10.8 | 39.0 | 0.013 |
4x2x0.5 | 28/0.15 | 10.5 | 12.5 | 39.0 | 0.013 |
8x2x0.5 | 28/0.15 | 12.8 | 14.8 | 39.0 | 0.013 |
2x2x0.75 | 30/0.15 | 8.2 | 10.2 | 26.0 | 0.011 |
2x2x1 | 32/0.15 | 10.4 | 12.4 | 19.5 | 0.010 |