GDX machine need to work with GUDA grooved belt,Belt Clip, Counter Pulley, Belt Breaking Detect,
Bake Release, Belt Lock.
GENERAL DATA | Load | Lift speed |
Phase Voltage |
Sheave dia |
Poles | Traction belt qty |
Rated power |
Rated speed |
Rated torque |
Frequ ency |
Rated Voltage |
Rated Current |
GDX132-1250-10-34 | 1250kg | 1m/s | 3/380V | 104mm | 10P | 4n | 8.4kW | 367r/min | 219N·m | 30.6Hz | 332V | 18.6A |
GDX132-1250-16-34 | 1250kg | 1.6m/s | 3/380V | 104mm | 10P | 4n | 13.4kW | 588r/min | 218N·m | 49Hz | 337V | 27.8A |
GDX132-1250-17.5-34 | 1250kg | 1.75m/s | 3/380V | 104mm | 10P | 4n | 14.7kW | 643r/min | 218N·m | 53.6Hz | 336V | 30.5A |
GDX132-1250-20-34 | 1250kg | 2m/s | 3/380V | 104mm | 10P | 4n | 16.8kW | 735r/min | 218N·m | 61.3Hz | 345V | 33.5A |
load | 1250kg |
Voltage | 380V |
Suspension | 2:1 |
Center Height | 132mm |
Weight | 190kg |
Max.Static Load | 4000kg |
Brake | DC110V 2*1.1A |
Duty | S5 40% |